 Solid State Relays Industrial, 1-Phase PS Types RC 24 .. -D 06, RC 44 .. -D 12
* * * * * * * AC Solid State Relay Peak switching for transformers Rated operational current: 10, 25 and 50 AACrms Non-repetitive voltage: Up to 1200 Vp Rated operational voltage: Up to 400 VACrms Input range: 4 to 32 VDC Insulation: OPTO (input-output) 4000 VACrms
Product Description
The peak switching relay is for switching on transformers/inductive loads in which the saturated iron core can cause severe inrush currents. The peak switching relay always switches ON at the first peak voltage in the AC sinusoidal curve after the control voltage is applied. The relay switches OFF when the current crosses zero.
Ordering Key
Solid State Relay Switching mode Rated operational voltage Rated operational current Control voltage Non-rep. peak voltage
RC 24 10 -D 06
Type Selection
Switching mode C: Peak switching Rated operational voltage 24: 230 VACrms 44: 400 VACrms Rated operational current 10: 10 AACrms 25: 25 AACrms 50: 50 AACrms Control voltage -D: 4 to 32 VDC Non-rep. voltage 06: 650 Vp 12: 1200 Vp
Selection Guide
Rated operational voltage 230 VACrms 400 VACrms Control voltage Rated operational current 10 AACrms 25 AACrms RC 2410 -D 06 RC 4410 -D 12 RC 2425 -D 06 RC 4425 -D 12 50 AACrms RC 2450 -D 06 RC 4450 -D 12
4 to 32 VDC 4 to 32 VDC
General Specifications
RC 24.. -D 06 Operational voltage range Non-rep. peak voltage Operational frequency range Power factor Approvals CE-marking 90 to 280 VACrms 650 Vp 45 to 65 Hz 0.5 @ 230 VACrms UL, CSA Yes RC 44.. -D 12 180 to 480 VACrms 1200 Vp 45 to 65 Hz 0.5 @ 400 VACrms UL, CSA Yes
Specifications are subject to change without notice (30.06.1999)
1
RC 24 .. -D 06, RC 44 .. -D 12
Input Specifications
Control voltage range Pick-up voltage Drop-out voltage Reverse voltage Input impedance Response time pick-up Response time drop-out Input pulse, rise/fall time 4 to 32 VDC 4 VDC 1 VDC 32 VDC 1 k 1/2 cycle 1/2 cycle 100 s
Insulation
Rated insulation voltage Input to output Rated insulation voltage Output to case Insulation resistance Input to output Insulation resistance Ouput to case Insulation capacitance Input to output Insulation capacitance Output to case 4000 VACrms 4000 VACrms 1010 1010 8 pF 50 pF
Output Specifications
RC .. 10 -D .. Rated operational current AC1 Minimum operational current Rep. overload current t=1 s Non-rep. surge current t=20 ms Off-state leakage current @ rated voltage and frequency I2t for fusing t=1-10 ms Critical dI/dt On-state voltage drop @ rated current Critical dV/dt commutating Critical dV/dt off-state 10 Arms 100 mArms 50 Ap 160 Ap 5 mArms 130 A2s 100 A/s 1.6 Vrms 1 kV/s 1 kV/s RC .. 25 -D .. 25 Arms 100 mArms 80 Ap 250 Ap 5 mArms 310 A2s 100 A/s 1.6 Vrms 1 kV/s 1 kV/s RC .. 50 -D .. 50 Arms 100 mArms 175 Ap 600 Ap 5 mArms 1800 A2s 100 A/s 1.6 Vrms 1 kV/s 1 kV/s
Thermal Specifications
RC .. 10 -D .. Operating temperature Storage temperature Junction temperature Rth junction to case Rth junction to ambient -20 to +70C (-4 to +158F) -40 to +100C (-40 to +212F) 125C (257F) 2 K/W 12.5 K/W RC .. 25 -D .. -20 to +70C (-4 to +158F) -40 to +100C (-40 to +212F) 125C (257F) 1.25 K/W 12 K/W RC .. 50 -D .. -20 to +70C (-4 to +158F) -40 to +100C (-40 to +212F) 125C (257F) 0.65 K/W 12 K/W
Wiring Diagram
Functional Diagram
Mains input/load output
Control input
Line/load
Control input
Load output/mains input
2
Specifications are subject to change without notice (30.06.1999)
RC 24 .. -D 06, RC 44 .. -D 12
Heatsink Dimensions
RC .. 10 -D ..
Load current [A] Thermal resistance [K/W]
(load current versus ambient temperature)
RC .. 25 -D ..
Power dissipation [W] Load current [A] Thermal resistance [K/W] Power dissipation [W]
16 15 14 13 12 11 10 9 7 5 3 1
2.7 3.1 3.7 4.3 5 5.9 6.9 7.9 10.8 20
2.2 2.6 3.1 3.7 4.3 5.1 6 6.9 9.5 14.2 30
1.8 2.1 2.6 3.1 3.7 4.4 5.2 5.9 8.1 12.2 40
1.3 1.7 2 2.5 3 3.6 4.3 4.9 6.8 10.2 50
0.87 1.2 1.5 1.9 2.3 2.8 3.5 4 5.4 8.1 14.6 60
0.41 0.65 0.92 1.2 1.6 2.1 2.6 3 4.1 6.1 10.9 70
22 20 18 16 15 13 12 10 7 5 3 1
TA
25 22.5 20 17.5 15 12.5 10 7.5 5 2.5
2 2.5 3.1 4.0 4.9 6.2 8.1 11.3 20
1.7 2.1 2.7 3.5 4.3 5.4 7.1 9.9 15.6 30
1.4 1.8 2.3 3 3.7 4.6 6.1 8.5 13.3 40
1 1.4 1.9 2.5 3.1 3.9 5.1 7.1 11.1 50
0.71 1 1.4 2 2.5 3.1 4 5.6 8.9 18.7 60
0.40 0.66 1 1.4 1.9 2.3 3 4.2 6.7 14 70
32 27 23 20 16 13 10 7 5 2
TA Ambient temp. [C]
Ambient temp. [C]
RC ..50 -D ..
Load current [A] Thermal resistance [K/W] Power dissipation [W]
Heatsink Selection
Carlo Gavazzi Heatsink (see Accessories)
0.29 0.44 0.63 0.89 1.2 1.5 2 2.7 4.3 8.9 60 0.26 0.42 0.63 0.91 1.1 1.5 2.1 3.2 6.7 70 63 55 47 40 33 26 20 15 9 4
TA
Thermal resistance Rth s-a > 12.5 3.0 0.8 0.25 < 0.25 K/W K/W K/W K/W K/W
50 45 40 35 30 25 20 15 10 5
0.92 1.2 1.5 1.9 2.4 3 3.9 5.5 8.6 17.9 20
0.76 0.99 1.3 1.6 2.1 2.7 3.5 4.8 7.5 15.6 30
0.60 0.80 1.1 1.4 1.8 2.3 3 4.1 6.4 13.4 40
0.45 0.62 0.85 1.1 1.5 1.9 2.5 3.4 5.4 11.2 50
No heatsink required RHS 100 Assy RHS 301 Assy RHS 301 F Assy Consult your distributor
Compare the value found in the current versus temperature chart with the standard heatsink values and select the heatsink with the next lower value.
Ambient temp. [C]
Specifications are subject to change without notice (30.06.1999)
3
RC 24 .. -D 06, RC 44 .. -D 12
Applications
Timing Initial turn-on The line voltage must be present at least 1 period before the input voltage is applied. Line voltage
Dimensions
** *** ***
** = 0.4 mm *** = 0.5 mm
*** ***
Input voltage Min. 1 period Repetitive turn-on The input voltage must be lower than the drop out voltage limit at least 1 period before it is reapplied. Output voltage
**
Housing Specifications
Weight Housing material Base plate Potting compound Relay Mounting screws Mounting torque Control terminal Mounting screws Mounting torque Power terminal Mounting screws Mounting torque Approx. 110 g Noryl GFN 1, black Aluminium Polyurethane M5 1.5 Nm M3 x 6 0.5 Nm M5 x 6 2.4 Nm
Input voltage Min. 1 period Overvoltage protection As transformers can have varying stray inductances and stray capacitances, it is always advisable to use external overvoltage protection. Varistor diameter: 20 mm Varistor voltage for 240 V SSR: 250 VAC (RV 02) Varistor voltage for 440 V SSR: 480 VAC (RV 05)
Load Input voltage Supply voltage
Accessories
Protection cover Heatsinks DIN rail adapter Varistors Fuses For further information refer to "General Accessories".
4
Specifications are subject to change without notice (30.06.1999)


▲Up To Search▲   

 